我们的网站为什么显示成这样?

可能因为您的浏览器不支持样式,您可以更新您的浏览器到最新版本,以获取对此功能的支持,访问下面的网站,获取关于浏览器的信息:

|本期目录/Table of Contents|

核素心肌灌注显像在心肌梗塞诊治中的应用(PDF)

《心脏杂志》[ISSN:1009-7236/CN:61-1268/R]

期数:
1995年第1期
页码:
39-43
栏目:
综述
出版日期:
1995-01-01

文章信息/Info

Title:
-
作者:
沈钰如1 综述 马寄晓2 审校
1上海建工医院 上海 200083 2上海市第六人民医院 上海 200233
Author(s):
-
关键词:
-
Keywords:
-
分类号:
-
DOI:
-
文献标识码:
-
摘要:
-
Abstract:
-

参考文献/References

[1]Sinusas AJ.Cardiac imaging with techentium-99m labelled perfusion agents.Year Book of unclear medicine st Louist Mosby 1992;15~46.

[2]Verani MS.Thallium-201 SPECT in the asSessment of coronary artery diSease.Am.J Cardiol 1992;70:3E.

[3]Bonow RO,Dilsizian V. AsSeSSing viable myocardium with thallium-201.Am.J Cardiol l992;70:10E.

[4] Heo J,Hernmn GA,Iskandrian AS,et al.New myocardial perfusion imaging agents,description and application.Am Heart J 1988;ll5:1111.

[5]Iskandrian AS.Thallium reperfusion imaging:the search for an optimal protoc01.tl Nucl Med 1 993;34:743.

[6]Diisizian V,Rocco TP,Fredman NMT,et al.Enhanced detection of ischemic but viable myocardium by the reinjection of thallium after stress redistribution imaging.N Engl J Med 1990;323:141.

[7]Kiat H,Friedman JD,Wang FP,et a1.Frequency of late reversibility in stress-redistribution thallium-201 SPECT using an early reinjection protocol.Am Heart J 1991;122:613.

[8]Basu S.Sridhara B,Senior R,et a1.Role of thallium201 reinjection in the assessment of myocardial viability following myocardial infarction.Br Heart J 1993;69(Suppl):6l.

[9]Maublant JC,Lipieck J,Citron B,et a1.Reperfusion as an alternative to rest lmaging for detectton of exercise Induced ischemia with thallium-201 SPECT.Am,Heart J 1993;1 25:330.

[10]Obtni H,Tanlaki N,Yonekura Y,et a1.Value of thallium-201 reinjection after delayed SPECT imaging for predicting reversible ischemia after coronary artery bypass grafting.Am J Cardiol 1990;66:394.

[11] Leppo JA,Depuey EG,JohnSon L.A review of cardiac imaging with sestamibi and teboroxime.J Nucl Med l99l;32:2012.

[12] Heo J,Kegel J,Iskandrian AS,et aL.CompariSson of saille-day protocols using technetium-99m-sestamibi myocardial inmging.J Nucl Med 1992;33:186.

[13]DePuey EG,Jones ME,Garcia EV.Evaluation of right ventricular regional pedusion with technetium-99m-ses-tamibi SPECT J Nucl Med 199l;32:1199.

[14]Marcassa C,Mazulla P,Parodi O,et a1.A new method for noninvasive quantification of segmental myocardial wall thickening,using technetium-99m-2-methoxy-isobutyl isonitrile Scintigraphy:results in norlnal subjects.J Nucl Med 1993;31:173.

[15]Weinstein H,Dahlheng ST,Mc Shery BA,et a1.Redistribution of teboroxime.Am J Cardiol l993;71:848.

[16]TaiUefer R,Lanlbert R,Essiambre R,et a1.Comparison between thallium-201,technetium-99m-sestamibi and technetium-99m+teboroxime planar myocardial perfusion imaging in detection of coronary artery disease.J Nucl Med 1992;33:1091.

[17]Verani MS,Borges-Neto S,Mahmarian JJ,et al.Quanifilcation of myocardial infarction during coronary occlusion and myocardial salvage after reperfusion using cardiac imaging with technetium-99m-MIBI.J Coll Cardiol 1988;12:1573.

[18]Olover DK,Okuda D.Myocardial technetium-99m-ses-tamibi kinetics alter reperluslon in a canine model.Am Heart J l993;l25:657 .

[19] Hvid-Jacobin R,Moiler JT,KjoHer E,et al.Myocardial perfusion at fatal infarction:Location and size of Sscintigraphic defects.J Nucl Med 1992;33:251.

[20]Gibbons RJ,Verani MS,Beehrenbeek T,et al,Feasiability of tomographic technetium-99m-MIBI imaging for the asseSsment of myocardial area at risk and the effect of treatment in acute nmyocardial infarction.Circulation 1989;90:1277.

[21]Gregoric J,Theroux P.Detection and assessment of unstable angina using myocardial perfusion imaging:cornparison between technetium-99m-MIBI and 12 lead elec trocardiogram.Am.J Cardiol 1990;66:42E.

[22]Cuocolo A,Pace L,Ricciadelle.B,et a1.Identification of viable myocardium in patients Wlth chronic coronary artery disease:rtery disease:comparison of thallium-201 scintigraphy with reinjection and technetium-99m-methoxyisobutyl isonitrile.J Nud Med 1992;33:505.

[23]Wackers FJTh.Comparson of thallium-201 and technetiunl-99m—methoxyisobutyl isonitrile.Am J Cardiol 1992;66:36E.

[24]Pellika PA,Behrenbeck T,Verani MS,et a1.Serial changes in myocardial perfusion using tomographic technetium-99m-hexakis-methoxy-2-methypropyl-isonitrile imaging following reperfusion therapy of myocardial infarction.J Nucl Med 1990;31:1269.

[25]Mahmarian JJ,Pratt CM,Boyce TM,et a1.The variable extent of jeopardized myocardium in patients with single vessel coronary artery dIsease;quantification by thallium-201 SPECT,J Am Coil Cardiol 1991;17:355.

[26] Leppo JA.Dipyridamole-thallium imaging.The lazyman’s stress test.J Nucl Med 1980;30:281.

[27]Verani MS,Mahmarian JJ,Hixson JB,et al.Diagnosis of coronary artery disease by controlled coronary vasodilatation with adcnosin and thallium-201 Scintigraphy in patients unable to exercise.Circulation 1990;82:80.

[28]Lee J,Heo J,Ogilby JD,et a1.Atrioventricular block during adenosin thallium imaging. Am,Heart J 1992;123:1569.

[29]OKeefe JM,Dateman TM,Silvetrier T,et a1.Stfety and diagnostic accuracy of adenosin thallium-201scintigraphy in patients unable to exercise and those with LBBB.Am Heart.J 1992,124:614.

[30]Iskandrian AS,Lemlek J,Ogilby JD.et al.Early thailium imaging after percutaneous transluminal coronary angiography:tomographic evaluauon during adenosine induced coronary hypoxemia.J Nucl Med 1992;33:2086.

[31]Verani MS,Mahnmrian JJ.Myocardial Scintigraphy durillg maxinml coronary artery vasodilation with adenosin.Am.J Cardiol 1991;67:12TD.

[32]Verzijilbergen JF,Suttorp MJ.Ascoop PI,et a1.Combined assessnment of technetium-99m-sestamibi planarmyocardial perfusion images at rest and during exercise with rest/exercise left ventncular wall motion studles evaluated from gated myocardial pedusion studies.Am Hert J l992;123:59 .

[33]Pirelli S,Danzi GB,Massa D,et al.Exercise thallium scintigraphy versus high dose dipyridamole echocardio graphy testing for detection of asymptomatic restenosis in patients with positive exercise test after coronary angiography.Am.J Cardiol 1993;71:1052.

[34]Marzullo P,Parodi O,Reisenhofer B,et al.Value ofrest thallium-201,technetium-99m-sestamibi scans and dobutamine echocardiography for detecting myocardial viablity.Am J Cardiol 1993;71:166.

[35]Kurata C,Tauarhara K,TagucHi T,et a1.Lung thalli-um-201 uptake during exercise emission computed tomography.J Nucl Med 1991;32:417.

[36]Hecht HS,Shaw KE,Bruce TR,et al.Usefulness of tomographic thallium-201 for detection of restenosis after PTCA.Am J Cardiol 1990;66:1314.

[37]Liu XJ,et a1.Proceedings of World Chinese Conference of Nuclear Medicine l993:33.

备注/Memo

备注/Memo:
收稿 1993-10-13
更新日期/Last Update: 1995-01-01