我们的网站为什么显示成这样?

可能因为您的浏览器不支持样式,您可以更新您的浏览器到最新版本,以获取对此功能的支持,访问下面的网站,获取关于浏览器的信息:

|本期目录/Table of Contents|

联合应用切割球囊与放射治疗对冠脉支架内再狭窄的作用(PDF)

《心脏杂志》[ISSN:1009-7236/CN:61-1268/R]

期数:
2003年第4期
页码:
344-346,349
栏目:
介入治疗
出版日期:
2003-07-01

文章信息/Info

Title:
The effect of cutting balloon combined brachytherapy after coronary angioplasty on in-stent restenosis
作者:
陆士娟1SengjueTahk2
1.海口市心血管病研究所,海口市人民医院心内科,海南 海口 570208; 2.韩国亚洲大学医院心脏中心
Author(s):
LU Shi-juan1 Sengjue Tahk2
Haikou Institute of Cardiovascular Diseases, Department of Cardiology of the Municipal People's Hospital of Haikou, Haikou Hainan 570208, China
关键词:
冠状动脉疾病支架内再狭窄切割球囊近距离放射治疗
Keywords:
coronary disease in-stent restenosis cutting balloon brachytherapy
分类号:
R541.4
DOI:
-
文献标识码:
A
摘要:
目的:探讨联合应用切割球囊及β射线(166Ho)冠脉内放射治疗对支架内再狭窄的作用。方法:对2001-01~2002-03韩国亚洲大学医院心脏中心完成的60例支架内再狭窄的患者,全部使用切割球囊预扩张,满意扩张后使用充满液态166Ho的长球囊(30~40mm)进行冠脉内放射治疗。术后随访主要临床不良事件,并于术后8个月行冠状动脉造影,用MEDCONViewer软件包进行定量冠状动脉造影(QCA)分析。结果:60例患者65处支架内再狭窄病变均被满意扩张,血管内放射治疗全部成功,无撕裂、血栓形成等并发症。随访8个月,无1例死亡。5例(8.3%)于术后3个月出现心绞痛行靶病变血管重建术,其余55例患者均于术后8个月行冠状动脉造影,4例于支架内发生再狭窄(7.3%),6例于支架边缘发生再狭窄(10.9%),全部患者无晚期血栓形成、假性动脉瘤及冠状动脉瘤发生。病变长度为25.1±4.7mm。晚期管腔丧失为0.19±0.68mm。最小管腔直径术前为0.38±0.26mm,术后即刻为2.08±0.36mm,8个月随访时为1.82±0.76mm。结论:联合应用切割球囊及β射线(166Ho)冠脉内放射治疗对支架内再狭窄是有效及安全的,可在临床推广应用。
Abstract:
AIM: To evaluate the effect of intracoronary brachytherapy using 166Ho after cutting balloon angioplasty on in-stent restenosis. METHODS: The total 65 lesions of 60 patients with in-stent restnosis in Cardiovascular Center of Ajou University Hospital Koren from January 2001 to March 2002 were treated using long balloon which was filled with 166Ho solution after cutting balloon angioplasty. Follow-up angiography and quantitative coronary angiography (QCA) were performed after 8 months of the therapy, in which the QCA was performed by MEDCON Viewer QCA softwar epackage. RESULTS: The procedures were successful in all 60 patients (100%). No complications occurred. Target vessel revascularizations were done in 5 cases (8.3%) during 3 months of post-procedure. Follow-up angiographies were performed in 55 cases after 8 months, among whom binary(?) restenosis in stent segments were discovered in 4 cases (7.3%) and those in edge segment in 6 cases (10.9%).The minimum luminal diameter was 0.38±0.26mm before angioplasty, 2.08±0.36mm immediately after angioplasty and 1.82±0.76mm at 8 months' follow-up. The lesion length was 25.1±4.7mm. No coronary aneurysm and pseudoaneurysm were complicated. CONCLUSION: The brachytherapy using 166 Ho after cutting balloon angioplasty on in-sten trestenosis maybe safe and feasible.

参考文献/References

[1] Kim HS, Waksman R, Cottin Y, et al. Edge stenosis and geographical miss following intracoronary gamma radiation therapy forin-stent restenosis [J] . J Am Coll Cardiol, 2001, 37:1026-1030.

[2] Willem J, Patrick W. β-Particle-Emitting stents radiate enthusiasm in the search for effective prevention of restenosis [J] . Circulation, 1996, 94:2358-2360.

[3] Kondo T, Kawaguchi K, Awaji Y, et al. Immediate and chronic results of cutting balloon angioplasty: a matched comparison with conventional angioplasty [J] . Clin Cardiol, 1997, 20:459-463.

[4] Fareh J, Martel R, Kermani P, et al. Cellular effects of β-Particle delivery on vascular smooth muscle cells and endothelial cells: a dose-response study [J] . Circulation, 1999, 99:1477-1484.

[5] Joh CW, Park CH, Kang HJ, et al. Measurement of radiation absorbed dose in endovascular 166Ho brachytherapy using a balloon angio-catheter [J] . Nucl Med Commun, 2000, 21(10):959-964.

[6] Leon MB, Teirstein PS, Moses JW, etal. Localized intracoronary gamma-radiation therapy to inhibit there currence of restenosis after stenting [J] . N Engl J Med, 2001, 344:250-256.

[7] Popma J. Late Clinical and angiographic outcomes after use of 90Sr/90y beta radiation for the treatment of in-stent restenosis: results from the 90Sr Treatment of Angiographic Restenosis (START) Trial [J] . J Am Coll Cardiol, 2000, 35:311-312.

[8] Raizner AE, Oesterle SN, Waksman R, et al. Inhibition of restenosis with beta-emitting radiotherapy: report of the proliferation reduction with vascular energy trial (PREVENT) [J] . Circulation, 2000, 102:951-958.

[9] Waksman R, Ajani AE, White RL, et al. Prolonged antiplatelet therapy to prevent late thrombosis after intracoronary gamma-radiation in patients with in-stent restenosis: Washington Radiation forIn-stent Restenosis Trial plus 6 months of clopidegrel (WRISTPLUS) [J] . Circulation, 2001, 103:2332-2335.

[10] Condado JA, Waksman R, Gurdiel O, et al. Long-term angiographic and clinical outcome after percutaneous transluminal coronary angioplasty and intracoronary radiation therapy in humans [J] . Circulation, 1997, 96:727-732.

备注/Memo

备注/Memo:
收稿日期:2003-03-18.
更新日期/Last Update: 2003-07-01