介绍部分二氧化碳复吸入法无创心排出量监测的原理以及临床应用的研究进展。该法基于Fick原理,操作简便,价格相对较低,无需特殊的技术操作,与有创监测相关性好,且可避免有创监测带来的并发症,是一种值得推广的监测手段。
Abstract:
-

参考文献/References

[1] Gedeon A, Forslund L, Hedenstierna G, et al. A new method for noninvasive bedside determination of pulmonary blood flow [J] . Med Bio Eng Comput, 1980, 18:411-418.

[2] Capek JM, Roy RJ. Noninvasive measurement of cardiac output using partial CO2 rebreathing [J] . IEEE Trans Biomed Eng, 1988, 35:653-661.

[3] Genoni M, Pelosi P, Romand JA, et al. Determination of cardiac output during mechanical ventilation by electrical bioimpedance or thermodilution in patients with acute lung injury [J] . Crit Care Med, 1998, 26(8):1441-1445.

[4] Haryadi DG, Joseph AO, Kai K, et al. Evaluation of a partial CO2 rebreathing Fick technique for measurement of cardiac [J] . Anesthesiology, 1998, 89(3A):A534.

[5] Kuck K, Dipl-In G, Dinesh GH, et al. Evaluation of partial rebreathing cardiac output measurement during surgery [J] . Anesthesiology, 1998, 89(3A):A542.

[6] Gabrielsen A, Videbaek R, Schou M, et al. Non-invasive measurement of cardiac output in heart failure patients using a new foreign gas rebreathing technique [J] . Clin Sci (Lond), 2002, 102(2):247-252.

[7] Tsujimoto S, Arimura Y, Kuroda N, et al. Introduction and clinical evaluation of a new non-invasive cardiac output monitor (NICO) based on Fick partial CO2 rebreathing method [J] .Masui, 2001, 50(7):799-804.

[8] NilssonL B, Eldrup N, Berthelsen PG. Lack of agreement between thermodilution and carbon dioxide-rebreathing cardiac output [J] . Acta Anaesthesiol Scand, 2001, 45(6):680-685.

[9] van Heerden PV, Baker S, Lim SI, et al. Clinical evaluation of the non-invasive cardiac output (NICO) monitor in the intensive care unit [J] . Anaesth Intensive Care, 2000, 28(4):427-430.

[10] Maxwell RA, Gibson JB, Slade JB, et al. Non invasive cardiac output by partial CO2 rebreathing after severe chest trauma [J] . J Trauma, 2001, 51(5):849-853.

[11] Tachibana K, Imanaka H, Miyano H, et al. Effect of ventilator settings on accuracy of cardiac output measurement using partial CO2 rebreathing [J] . Anesthesiology, 2002, 96:96-102.

备注/Memo