我们的网站为什么显示成这样?

可能因为您的浏览器不支持样式,您可以更新您的浏览器到最新版本,以获取对此功能的支持,访问下面的网站,获取关于浏览器的信息:

|本期目录/Table of Contents|

介入法治疗室间隔缺损修补术后残余漏(PDF)

《心脏杂志》[ISSN:1009-7236/CN:61-1268/R]

期数:
2005年第2期
页码:
163-165
栏目:
介入治疗
出版日期:
2005-03-05

文章信息/Info

Title:
Transcatheter closure of residual fistula after surgery repair of ventricular septal defect
作者:
张玉顺1贾邵斌2王震3代政学1李寰1李军1张军1
1.第四军医大学西京医院, 陕西 西安 710032;2.宁夏医学院附属医院;3.河北医科大学第一附属医院
Author(s):
ZHANG Yushun1 JIA Shaobin2 WANG Zhen3 DAI Zhengxue1 LIHuan1 LI Jun1 ZHANG Jun1
1.Xijing Hospital, Fourth Military Medical University, Xi′an, Shaanxi 710032, China; 2.Affiliated Hospital of Ninxia Medical University; 3.First Affiliated Hospital of Hebei Medical University
关键词:
室间隔缺损残余分流手术封堵
Keywords:
ventricular septal defect residual shunt surgery occlude
分类号:
R541.1
DOI:
-
文献标识码:
A
摘要:
目的 评价室间隔缺损(VSD)修补术后经导管封堵治疗的临床效果。方法 9(男4,女5)例患者,年龄5~40岁。其中膜部VSD术后7例,法洛四联症(TOF)术后2例。经胸超声心动图测量VSD术后残余漏直径为3~12 mm。有7例为1个残余漏口,2例有2个残余漏口。结果 左心室造影5例膜部瘤的左室面直径14~28 mm,漏口均在膜部瘤的出口。其中3例残余漏有1个孔,其大小分别为4、6和7 mm,用6、9和10 mm VSD封堵器。2例有2个孔,其大小分别为3、6 mm 和9、7 mm,两孔之间距离分别为8和10 mm,均放置两个封堵器,1例为5和9 mm VSD封堵器,1例为14 mm VSD封堵器和12/14 mm动脉导管未闭封堵器。2例膜部VSD,其漏口直径分别为3和10 mm,用5和14 mm封堵器。2例TOF术后并发VSD残余漏,其漏口直径分别为9和14 mm,用12和18 mm封堵器。术后即刻左心室造影8例无残余分流,1例两个封堵器的患者有少量残余分流。升主动脉造影全部患者无主动脉瓣返流。随访1~6月复查超声心动图,有残余分流的1例在3月消失,全部患者封堵器无移位,无主动脉瓣返流。结论 经导管封堵治疗室间隔缺损修补术后残余漏是一项操作安全、疗效可靠的治疗方法。
Abstract:
AIM To evaluate the effect of transcatheter closure of residual fistula after surgery repair of ventricular septal defect (VSD). METHODS 9 (4 male, 5 female) patients, aged from 5 to 40, were investigated. In which 7 cases were postsurgery of membranous VSD, 2 cases were postsurgery of tetralogy of Fallot (TOF). The diameter of residual fistula measured by transthoracic echocardiography was from 3 to 12 mm. 7 cases with only 1 residual fistula, and another 2 cases with 2 residual fistulae. RESULTS In 5 cases, the diameter of membranous aneurysm of left ventricular measured by left ventriculography was from 14 to 28 mm, the fistulae were all in the exit of membranous aneurysm. Among them, one fistula was found in 3 cases, and the size of fistula was 4,6,and 7mm, respectively, and the implanted occluder was 6, 9, and 10 mm VSD occluder, respectively; 2fistula was found in 2 cases, and the size of fistula was 3/6 mm and 9/7 mm, respectively, the distance between the 2fistula was 8 and 10 mm, respectively, were all implanted with 2 occluders (1 with 5/9 mm VSD occluders, another with 14 mm VSD occluder and 12/14 mm PDA occluder).Another 2 membranous VSD, the diameter of fistula was 3 and 10 mm, respectively, the implanted occluder was 5 and 14 mm, respectively. 2 TOF residual fistula, the diameter of fistula was 9 and 14 mm, respectively, and the implanted occluder was 12 and 18 mm, respectively. Immediately after occlusion, by left ventriculography, no residual shunt was found in 8 cases, small residual shunt was found in 1 case implanted with 2 occluders. None was found aorta regurgitation by ascending aorta angiography. During 1~6 months followup, examined by echocardiography, 1 case residual shunt was disappeared after 3 month of occlusion; none was found occluder shift and aorta regurgitation. CONCLUSION Transcatheter closure of residual fistula after surgery repair of ventricular septal defect is a safe, with reliable results therapy.

参考文献/References

[1] 谷兴琳,戴约,钱龙宝,等. 室间隔缺损残余漏的防治与转归[J].中华胸心血管外科杂志,1996,12( 2) :282-283.

[2]潘建军. 二维彩色多普勒超声心动图诊断 VSD术后补片旁漏[J].中国医学影像技术,1993,9:39-41.

[3]潘世伟,刘迎龙,肖明第,等. 残余 VSD的外科治疗[J]. 中国循环杂志,1994,9:338-340.

[4]Gatzoulis MA,Clark AL,Cullen S,et al. Right ventricular diastolic function 15 to 35 years after repair of tetralogy of Fallot. Restrictive physiology predicts superior exercise performance[J]. Circulation, 1995,91:1775-1781.

[5]谢少东,黄映英,庄健. 彩色多普勒血流显像随诊观察室间隔缺损修补术后残余分流[J]. 中国超声医学杂志,1999,15:452-453.

[6]Hijazi ZM, Hakim F, Haweleh AA, et al. Catheter closure of perimembranous ventricular septal defects using the new Amplatzer membranous VSD occluder: Initial clinical experience[J]. Catheter Cardiovasc Interv, 2002, 56(4):508-515.

[7]张玉顺,代政学,贾国良,等. 国产双盘状封堵器经导管治疗膜部室间隔缺损疗效的初步评价[J].心脏杂志,2002,14(6):518-520.

[8]Bass JL, Kalra GS, Arora R, et al. Initial human experience with the Amplatzer perimembranous ventricular septal occluder device[J]. Cathet Cardiovasc Interv, 2003,58:238-245.

备注/Memo

备注/Memo:
收稿日期:2004-12-30.
更新日期/Last Update: 2010-01-05