Surface heparinization of polyvinyl chloride used for cardiopulmonary bypass system
作者:
段维勋1易定华1杨剑1 刘金成1 刘剑2曹瑞军2
1 .第四军医大学西京医院心脏外科,陕西 西安 710032;2. 西安交通大学理学院应用化学系, 陕西 西安 710049
Author(s):
DUAN Weixun1 YI Dinghua1 YANG Jian1 LIU Jincheng1LIU Jian2 CAO Ruijun2
1.Department of Thoracic and Cardiovascular Surgery, Xijing Hospital, Fourth Military Medical University, Xi′an 710032, Shaanxi, China; 2.Department of Applied Chemistry, School of Science, Xi′an Jiaotong University, Xi′an 710049,Shaanxi,China
关键词:
聚氯乙烯酯键共价键肝素
Keywords:
polyvinyl chloride(PVC) ester bonds covalent bond heparin
分类号:
R318.08
DOI:
-
文献标识码:
A
摘要:
目的 探讨体外循环系统聚氯乙烯材料表面共价结合肝素的方法,并对肝素化后聚氯乙烯材料的血液相容性及稳定性进行评估。方法 通过材料表面活化,引入活性位点放大剂及扩链剂,通过酯键将肝素分子共价结合到聚氯乙烯材料表面,并对肝素化后的聚氯乙烯材料进行肝素含量、肝素释放速率、体外抗凝血性能等检测。结果 肝素分子以酯键方式共价结合到聚氯乙烯材料表面,肝素结合量2~5 μg/cm2, 肝素释放速率测定显示该肝素化表面具有良好的稳定性,PT和APTT检测显示其具有良好的抗凝血性能。结论 通过酯键肝素共价键结合能提高聚氯乙烯材料表面肝素结合量,其稳定性和抗凝血性能良好。
Abstract:
AIM To explore a novel method to immobilize heparin onto the polyvinyl chloride (PVC) surface used for cardiopulmonary bypass system and to evaluate its bloodcompatibility and stability. METHODS Heparin was bonded to the PVC surface by urethane bonds after the use of amplification polymers. The surface heparin content, release velocity and ex vivo anticoagulation were then detected. RESULTS The surface heparin content was high about 2-5 μg/cm2. The release velocity result showed good stability. The product prolonged the PT and APTT significantly and had great anticoagulation activity. CONCLUSION This novel method can be used to combine the heparin onto PVC surface used for cardiopulmonary bypass system and to improve its biocompatibility.

参考文献/References

[1]Janvier G , Baquey C,Roth C, et al. Extracorporeal circulation,hemocompatibility, and biomaterials [J]. Ann Thorac Surg, 1996, 62(6): 1926-1934.

[2]Wendel HP, Ziemer G. Coatingtechniques to improve the hemocompatibility of artificial devices used for extracorporeal circulation[J]. Eur J Cardiothorac Surg, 1999, 16(3): 342-350.

[3]Hsu LC. Principles of heparincoating techniques[J]. Perfusion, 1991, 6(3): 209-219.

[4]杨万泰,尹梅贞. 表面光接枝技术及应用[J]. 影像技术,1998,(3): 5-10.

[5]孙永红,邱永兴,郑筱翔,等. 新型肝素化聚苯乙烯表面及其体外抗凝性的研究[J]. 中国生物医学工程学报, 2002, 21(2): 118-121.

[6]Smith PK, Mallia AK, Harmanam GT. Colorimetric method for the assay of heparin content in immobilized heparin preparations[J]. Aanl Bichem,1980, 109(2):466-473.

[7]Gott VL, Whiffen JD, Dutton RC. Heparin bonding on colloidal graphite surfaces [J]. Science, 1963, 142:1297-1298.

[8]高宁国,程秀兰,杨敬. 肝素结构与功能的研究进展[J]. 生物工程进展, 1999, 19(5): 4-13.

备注/Memo

备注/Memo:
收稿日期: 2005-19-20.基金项目:西安市科学技术创新基金项目资助(No.ZS200215) 通讯作者:易定华,主任医师,主要从事人工心脏、冠心病研究Email:yidh@fmmu.edu.cn 作者简介:段维勋,博士生Email: duanweix@fmmu.edu.cn
更新日期/Last Update: