我们的网站为什么显示成这样?

可能因为您的浏览器不支持样式,您可以更新您的浏览器到最新版本,以获取对此功能的支持,访问下面的网站,获取关于浏览器的信息:

|本期目录/Table of Contents|

应用国产心血管造影机进行经桡动脉与经股动脉途径冠心病介入治疗的比较 (PDF)

《心脏杂志》[ISSN:1009-7236/CN:61-1268/R]

期数:
2007年第4期
页码:
464-466/470
栏目:
临床研究
出版日期:
2007-08-01

文章信息/Info

Title:
A comparative study of intervention approaches in coronary heart disease: Transradial and transfemoral by Chinamade cardioangiographic system
作者:
许勇文亚红田巨龙罗晓辉徐大文钱昌明曾晓斌高红梅
攀枝花市中心医院心内科,四川 攀枝花 617067
Author(s):
XU Yong WEN Yahong TIAN Julong LUO Xiaohui XU Dawen QIAN Changming ZENG Xiaobin GAO Hongmei
Department of Cardiology, Central Hospital of Panzhihua, Panzhihua 617067, Sichuan, China
关键词:
经桡动脉途径经股动脉途径直接经皮冠状动脉介入术国产心血管造影机
Keywords:
transradial approachtransfemoral approachpercutaneous coronary interventionChinese cardioangiographic examination
分类号:
R541.4
DOI:
-
文献标识码:
A
摘要:
目的 比较应用国产心血管造影机进行经桡动脉和经股动脉途径冠心病介入治疗(PCI)的安全性和有效性。方法 我院2003年1月~2006年4月应用我国万东公司生产的大型C臂心血管造影机(CGO3000)对290例(163例男性)冠心病患者进行经桡动脉组(n=98)或经股动脉组( n=192)途径PCI治疗,观察两组手术成功率、并发症发生率、鞘管置入时间、X线曝光时间、手术时间及造影剂用量。结果 PCI总成功率99.3%,高于全国第3次PCI病例注册资料分析结果, 主要并发症发生率无增多。两组病例基线水平、增加出血的危险因素、病变复杂程度、支架置入血管、支架置入数无统计学意义;两组成功率、鞘管置入时间、X线曝光时间、手术时间、造影剂用量无统计学意义;A组血肿0例(0%)、B组21例(10.9%),A组血管迷走反射0例(0%)、B组21例(10.9%),A组皮肤破溃、感染0例(0%)、B组11例(5.7%),A组穿刺血管痉挛4例(4.1%)、B组0例(0%),A组不能入睡0例(0%)、B组184例(95.8%),A组腰背部疼痛0例(0%)、B组153例(79.7%),A组尿潴留0例(0%)、B组63例(32.8%), A组平均住院(4.2±0.6)d、B组(6.1±2.2)d,均P<0.05,有统计学意义。结论 经桡动脉途径是一种安全、有效、患者更容易接受的PCI方法,它与传统经股动脉途径互为补充。对有选择的病例桡动脉途径可首选。
Abstract:
AIM To investigate the safety and effectiveness of transradial approach by Chinamade Carm cardioangiographic system in the treatment of coronary heart diseases by comparing the main parameters obtained from transradial approach and transfemoral approach. METHODS From January 2003 to April 2006, percutaneous coronary intervention(PCI) was performed in 290 patients (160 males) with coronary heart disease via either transradial (Group A, n=98) or transfemoral approach (Group B, n=192) by Chinamade Carm cardioangiographic system (CGO3000). The success rate, the complications rate, the cannulation time, the Xray exposure time, the operation time and the amount of contrast consumed were recorded and compared. RESULTS The overall successful rate of PCI is 99.3%, higher than that of the 3rd national registered data of intervention, and the main complications rate is not increased. Comparing this two groups, the basic line level of patients, risk factors of bleeding, lesion complication, vessel implanted with stent, and stent number show no statistic significance; the successful rate, cannulation time, Xray exposure time, operation time, and the amount of contrast consumed have no statistic sense; the hematoma complications [A=0(0%) versus B=21(10.9%),P<0.05], vagus reflex complications[A=0(0%) versus B=21(10.9%),P<0.05],skin erosion and infection complications [A=0(0%) versus B=11(5.7%),P<0.05], puncture angiospasma complications [A=4(4.1%) versus B=0(0%),P<0.05], insomnia complications[A=0(0%) versus B=184(95.8%),P<0.05], lumbodorsalgia[A=0(0%) versus B=153(79.7%),P<0.05],urinary retention complications[A=0(0%) versus B=63(32.8%),P<0.05],and the average hospitalization time [A= (4.2±0.6)days versus (6.1±2.2)days ,P<0.05]show statistic significances.CONCLUSION The transradial approach, safer, more reliable and better accepted by patients, can be the first choice of intervention treatment for coronary heart diseases.

参考文献/References

[1] 周景昱,吕安林,贾国良,等. 经桡动脉与经股动脉两种途径冠心病介入治疗的对比研究[J].心脏杂志,2003,15(3):255-258.

[2] 侯爱洁,刘民 ,李占全,等. 经桡动脉PCI治疗急性心肌梗死的初步经验[J]. 岭南心血管病杂志,2003,9(5):316-319.

[3] 孙玲,李艳华 ,张迪,等. 经桡动脉途径的老年冠心病诊断和治疗[J].中国老年学杂志,2003,23(9):573-574.

[4] 韩雅玲,荆全民,王守力,等. 经桡动脉冠心病介入治疗165例报告[J]. 中国实用内科杂志,2003,23(4):214-215.

[5] 关英敏,吕安林,王海昌,等. 经桡动脉冠状动脉腔内支架术治疗冠状动脉复杂病变[J].心脏杂志 ,2005,17(1): 42-45.

[6] 中华医学会心血管病学分会介入心脏病学组,中华心血管病杂志编辑部. 全国第三次冠心病介入治疗病例注册资料分析[J].中华心血管病杂志,2002,30(12):719-723.

[7] 韩雅玲,荆全民,王守力,等. 直接冠状动脉支架置入术的前瞻性临床研究[J].中华心血管病杂志 ,2002,30(5):265-268.

[8] 吕树铮,陈韵岱. 冠脉介入诊治技巧及器械选择 [M].北京:人民卫生出版社,2003:30-41.

备注/Memo

备注/Memo:
收稿日期:2006-04-26.作者简介:许勇,副主任医师Email:xuyong000015@sina.com
更新日期/Last Update: