经导管人工主动脉瓣植入动物的实验方法及影像分析

《心脏杂志》[ISSN:1009-7236/CN:61-1268/R]

期数:
2013年第1期
页码:
35-037
栏目:
基础研究
出版日期:
2013-02-25

文章信息/Info

Title:
Transcatheter artificial aortic valve implantation: animal experiment and image analysis
作者:
李召峰12潘文志1周达新1沈 安1李永生3葛均波1
(复旦大学附属中山医院:1.心内科,3.血管外科,上海 200032;2.解放军第88医院心内科,山东 泰安 271000)
Author(s):
LI Zhaofeng12 PAN Wen zhi1 ZHOU Da xin1 SHEN An1 LI Yongsheng3 GE Junbo1
(1.Department of Cardiology, 3.Department of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai 200032, China; 2.Department of Cardiology, PLA 88 Hospital, Tai’an 271000, Shandong, China)
关键词:
导管人工主动脉瓣植入
Keywords:
catheter artificial aortic valve implantation
分类号:
R542.52
DOI:
-
文献标识码:
A
摘要:
目的:建立经导管人工主动脉瓣植入的动物实验方法,确定主动脉窦部造影的最佳投射体位,探讨经腹主动脉植入人工主动脉瓣的可行性、安全性。方法: 选取健康杂种大白猪10只,经右侧股动脉送入猪尾巴导管行左心室造影,确定主动脉窦部造影的最佳投射体位,测量主动脉窦部的直径;经右侧股静脉送入临时起搏电极至右心室,选择合适的起搏频率;经腹主动脉送入22F输送鞘管,观察经输送鞘管推送预载瓣膜支架球囊的可行性、安全性。结果: 左心室造影可在左前斜(30±2)°、头位(10±4)°清楚地显示主动脉窦部及冠脉开口。主动脉窦部的直径为(212±23) mm。实验动物可以耐受连续30 s的快速起搏(240~260次/min)。结论: 经腹主动脉途径植入人工主动脉瓣的方法可行、安全。在左前斜(30±2)°、头位(10±4)°可清楚地显示主动脉窦部。以240~260次/min的频率快速起搏可最大限度地减少血流对球囊的冲击,更好地实现瓣膜植入时的精确定位。
Abstract:
AIM: To establish a new method of transcatheter aortic valve implantation, to determine the optimal projecting position for the angiography of aortic sinus and to explore the feasibility and safety of this method. METHODS: Ten healthy hybrid pigs were enrolled in this study. A pigtail catheter was placed in the left ventricle through the right femoral artery for ventriculography. The optimal projection position was determined and the diameter of the aortic sinus was measured after left ventriculography. A temporary pacemaker electrode was placed in the right ventricle and the appropriate pacing frequency was selected. A 22F delivery catheter was inserted in the abdominal aorta and a balloon catheter mounted with an artificial valve stent was attempted to be pushed and pulled through the delivery catheter system. RESULTS: Aortic sinus and coronary artery were well demonstrated in the left anterior oblique position (30±2°) plus cranial (10±4°). The diameter of the aortic sinus was (212±23) mm. All pigs enrolled in this study safely endured a rapid pacing frequency (240-260/min) for ~30 sec. CONCLUSION: Implantation of artificial aortic valves through the abdominal aorta is feasible and safe. Aortic sinus and coronary artery are well demonstrated in the left anterior oblique position (30±2°) plus cranial (10±4°). Under the condition of right ventricular rapid pacing, the valve stent could be more accurately implanted into position and the impact of blood flow could be maximally decreased.

参考文献/References

[1]Iung B,Baron G,Butchart EG,et al.A prospective survey of patients with valvular heart disease in Europe:The Euro Heart Survey on Valvular Heart Disease[J].Eur Heart J,2003,24(13):1231-1243.

[2]Nkomo VT,Gardin JM,Skelton TN,et al.Burden of valvular heart diseases: a populationbased study[J].Lancet,2006,368(9540):1005-1011.

[3]Andersen HR,Knudsen LL,Hasenkam JM. Transluminal implantation of artificial heart valves.Description of a new expandable aortic valve and initial results with implantation by catheter technique in closed chest pigs[J].Eur Heart J,1992,13(5):704-708.

[4]Cribier A,Eltchaninoff H,Bash A,et al.Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis:first human case description[J].Circulation,2002,106(24):3006-3008.

[5]葛均波,周达新,潘文志,等.经皮主动脉瓣植入术一例及其操作要点[J].中国介入心脏病学杂志,2010,18(5):243-246.

[6]顾明标,宗刚军,白元,等.经导管主动脉瓣置换的实验方法和影像分析[J].介入放射学杂志,2009,18(3):217-219.

[7]Ussia GP,Barbanti M,Petronio AS,et al.Transcatheter aortic valve implantation:3 year outcomes of selfexpanding CoreValve prosthesis[J].Eur Heart J,2012,33(8):969-976.

[8]Petronio AS,De Carlo M,Bedogni F,et al.Safety and efficacy of the subclavian approach for transcatheter aortic valve implantation with the CoreValve revalving system[J].Circ Cardiovasc Interv,2010,3(4):359-366.

[9]Webb JG,Pasupati S,Achtem L,et al.Rapid pacing to facilitate transcatheter prosthetic heart valve implantation[J].Catheter Cardiovasc Interv,2006,68(2):199-204.

备注/Memo

备注/Memo:
收稿日期:2012-07-09.通讯作者:葛均波,主任医师,主要从事冠心病介入诊疗的应用与基础研究 Email:jbge@zshospital.sh.cn 作者简介:李召峰,主治医师,博士Email:lizhaofeng_1978@yahoo.com.cn 共同第一作者:潘文志,主治医师,博士Email:peden@sina.com
更新日期/Last Update: 2013-03-20