Title:
Application and assessment of Stent Boost in interventional therapy of coronary artery diseases
作者:
贾小伟张 蛟魏玉杰金至赓刘惠亮
(武警总医院心内科,北京 100039)
Author(s):
JIA Xiao-wei ZHANG Jiao WEI Yu-jie JIN Zhi-geng LIU Hui-liang
(Department of Cardiology, General Hospital, Armed Police Forces, Beijing 100039, China)
关键词:
支架增强显影技术冠状动脉动脉介入治疗支架
Keywords:
Stent Boost coronary artery diseases interventional therapy stent
分类号:
R543.3
DOI:
-
文献标识码:
A
摘要:
支架增强显影技术(Stent Boost,SB)是一种利用动态矫正的X线透视显影来增强支架可视化水平的新技术。与血管内超声(intravascular ultrasound,IVUS)相比,具有简易快捷、安全省时和经济的特点,无需经过特殊培训,可有效地指导经皮冠状动脉介入(percutaneous coronary intervention,PCI)治疗。本文将对SB的成像原理、临床应用及其局限性进行简要阐述。
Abstract:
Stent Boost is a powerful x-ray imaging modality that provides enhanced stent visualization by eliminating motion artifact. This technique is more convenient, safe and time-efficient compared to IVUS and has lower procedural costs as well as a shorter learning curve of laboratory catheterization personnel. It can be used to guide PCI powerfully. In this article, we briefly review the imaging theory, clinical applications and limitations of Stent Boost.

参考文献/References

[1]King SB 3rd,Smith SC Jr,Hirshfeld JW Jr,et al.2007 focused update of the ACC/AHA/SCAI 2005 guideline update for percutaneous coronary intervention:a report of the American College of Cardiology/American Heart Association Task Force on Practice guidelines[J].J Am Coll Cardiol,2008,51(2):172-209.
[2]Antman EM,Hand M,Armstrong PM,et al.2007 focused update of the ACC/AHA 2004 guidelines for the management of patients with ST-elevation myocardial infarction:a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines[J].J Am Coll Cardiol,2008,51(2):210-47.
[3]Anderson JL,Adams CD,Antman EM,et al.ACC/AHA 2007 guidelines for the management of patients with unstable angina/non-ST-elevation myocardial infarction:a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines(Writing Committee to Revise the 2002 Guidelines for the Management of Patients With Unstable Angina/Non-ST-Elevation Myocardial Infarction):developed in collaboration with the American College of Emergency Physicians, the Society for Cardiovascular Angiography and Interventions, and the Society of Thoracic Surgeons endorsed by the American Association of Cardiovascular and Pulmonary Rehabilitation and the Society for Academic Emergency Medicine[J].J Am Coll Cardiol,2007,50(7):e1-e157.
[4]Fischman DL,Leon MB,Baim DS,et al.A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease.Stent Restenosis Study Investigators[J].N Engl J Med,1994,331(8):496-501.
[5]Stettler C,Wandel S,Allemann S,et al.Outcomes associated with drug-eluting and bare-metal stents: a collaborative network meta-analysis[J].Lancet,2007,370(9591):937-948.
[6]Stone GW,Moses JW,Ellis SG,et al.Safety and efficacy of sirolimus- and paclitaxel-eluting coronary stents[J].N Engl J Med,2007,356(10):998-1008.
[7]Fujii K,Carlier SG,Mintz GS,et al.Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantation:an intravascular ultrasound study[J].J Am Coll Cardiol,2005,45(7):995-998.
[8]Fujii K,Mintz GS,Kobayashi Y,et al.Contribution of stent underexpansion to recurrence after sirolimuseluting stent implantation for in-stent restenosis[J].Circulation,2004,109(9):1085-1088.
[9] Alfonso F,Suarez A,Angiolillo DJ,et al.Findings of intravascular ultrasound during acute stent thrombosis[J].Heart, 2004,90(12):1455-1459.
[10]Fujii K,Carlier SG,Mintz GS,et al.Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantation:An intravascular ultrasound study[J].J Am Coll Cardiol,2005,45(7):995-998.
[11]Sarno G,Garg S,Gomez-Lara J,et al. Intravascular ultrasound radiofrequency analysis after optimal coronary stenting with initial quantitative coronary angiography guidance: an ATHEROREMO sub-study[J].EuroIntervention,2011,6(8):977-984.
[12]Tanigawa J,Barlis P,Di Mario C.Intravascular optical coherence tomography:Optimisation of image acquisition and quantitative assessment of stent strut apposition[J].EuroIntervention,2007,3(1):128-136.
[13]Fearon WF,Luna J,Samady H,et al.Fractional flow reserve compared with intravascular ultrasound guidance for optimizing stent deployment[J].Circulation,2001,104(16):1917-22.
[14]Mishell JM,Vakharia KT,Ports TA,et al.Determination of adequate coronary stent expansion using StentBoost,a novel fluoroscopic image processing technique[J].Catheter Cardiovasc Interv,2007,69(1):84-93.
[15]Agostoni P,Verheye S.Bifurcation stenting with a dedicated biolimus-eluting stent:X-ray visual enhancement of the final angiographic result with“StentBoost subtract”[J].Catheter Cardiovasc Interv,2007,70(2):233-236.
[16]Agostoni P,Verheye S,Vermeersch P,et al.“Virtual” in-vivo bench test for bifurcation stenting with“Stent-Boost”[J].Int J Cardiol,2008,133(2):e67-e69.
[17]Vydt T,Van Langenhove G.Facilitated recognition of an undeployed stent with StentBoost[J].Int J Cardiol,2006,112(3):397-398.
[18]Blasini R,Neumann FJ,Schmitt C,et al.Comparison of angiography and intravascular ultrasound for the assessment of lumen size after coronary stent placement:impact of dilation pressures[J].Cathet Cardiovasc Diagn,1997,42(2):113-119.
[19]Eng MH,Klein AP,Wink O,et al.Enhanced stent visualization:A case series demonstrating practical applications during PCI[J].Int J Cardiol,2010,141(1):e8-e16.
[20]Silva JD,Carrillo X,Salvatella NA,et al.The utility of stent enhancement to guide percutaneous coronary intervention for bifurcation lesions[J].EuroIntervention,2013,9(8):968-974.
[21]Fysal Z,Hyde T,Barnes E,et al.Evaluating stent optimisation technique(StentBoost?) in a dedicated bifurcation stent(the tryton?)[J].Cardiovasc Revasc Med,2014,15(2):92-96.
[22]Oh DJ,Choi CU,Kim SW,et al.Effect of StentBoost imaging guided percutaneous coronary intervention on mid-term angiographic and clinical outcomes[J].Int J Cardiol,2013,168(2):1479-1484.
[23]Jin ZG,Yang SL,Jing LM,et al.Impact of StentBoost subtract imaging on patient radiation exposure during percutaneous coronary intervention[J].Int J Cardiovasc Imaging,2013,29(6):1207-1213.
[24]Colombo A,Hall P,Nakamura S,et al.Intracoronary stenting without anticoagulation accomplished with intravascular ultrasound guidance[J].Circulation,1995,91(6):1676-1688.

备注/Memo

备注/Memo:
收稿日期:2014-08-15.
通讯作者:刘惠亮,教授,主要从事心血管介入研究 Email:LhL518@sina.com
作者简介:贾小伟,硕士生 Email:jiaxiaowei1226@sina.com
更新日期/Last Update: 2015-04-22