我们的网站为什么显示成这样?

可能因为您的浏览器不支持样式,您可以更新您的浏览器到最新版本,以获取对此功能的支持,访问下面的网站,获取关于浏览器的信息:

|本期目录/Table of Contents|

埋藏式起搏器安置术同时行冠状动脉造影的安全性(PDF)

《心脏杂志》[ISSN:1009-7236/CN:61-1268/R]

期数:
2008年第2期
页码:
177-179
栏目:
临床研究
出版日期:
2008-03-20

文章信息/Info

Title:
Safety evaluation of patients treated with implanted pacemaker and coronary angiography
作者:
钱骏1郑金旭1孙广辉1严金川1杜荣增1任雨笙2
1.江苏大学附属医院心内科,江苏 镇江 212001;2.第二军医大学长征医院心内科,上海 200003
Author(s):
QIAN Jun1 ZHENG Jinxu1 SUN Guanghui1 YAN Jinchuan1 DU Rongzeng1 REN Yusheng2
1.Department of Cardiovascular Diseases, Affiliated Hospital to Jiangsu University, Zhenjiang 212001, Jiangsu, China; 2.Department of Cardiovascular Diseases, Changzheng Hospital, Second Military Medical University, Shanghai, 200003, China
关键词:
埋藏式起搏器安置术 冠状动脉造影 囊袋出血
Keywords:
coronary disease bradyarrhythmiapacemaker implantation coronary arteriography pocket bleeding
分类号:
R541.7;R814.43
DOI:
-
文献标识码:
A
摘要:
目的 探讨安置埋藏式起搏器的患者同时行冠状动脉造影(CAG)的安全性。方法 收集我院2006年1月~2007年3月58例埋藏式起搏器安置患者资料,以是否同时行CAG分为造影组22例与非造影组36例,观察冠心病在缓慢型心律失常患者中的比例,以及起搏器囊袋出血情况。结果 造影组22例患者中16例为冠心病,占73%。 起搏器安置的囊袋出血情况,造影组为4例占18%,非造影组为6例占17%,无显著差异。结论 埋藏式起搏器安置术同时行CAG没有增加囊袋出血,两者同时进行是安全的。
Abstract:
AIM To evaluate the safety of patients who had received treatment of implanted pacemaker and selected coronary angiography. METHODS Fiftyeight hospitalized patients who had received treatment of implanted pacemaker in our hospital from January 2006 to March 2007 were retrospectively analyzed. The subjects were divided into two groups: Group A of 22 patients who were treated with implanted pacemaker and selected coronary angiography and group B of 36 patients who were treated with only implanted pacemaker and coronary angiography. The proportion of coronary heart disease in patients with bradyarrythmia and pacemaker pocket bleeding was observed. RESULTS Among the 22 patients in group A, 16 had coronary heart disease, accounting for 73%: Four cases (18%) in group A suffered from pocket bleeding after pacemaker implantation and 6 cases (17%) in group B. CONCLUSION The treatment of implanted pacemaker and selected coronary angiography will not increase pocket bleeding. Pacemaker implantation after coronary arteriography is safe.

参考文献/References

[1] 中华医学会心电生理和起搏分会, 中国生物医学工程学会心脏起搏与电生理分会. 全国心脏起搏器和埋藏式心脏复律除颤器临床应用调查[J]. 中国心脏起搏与心电生理杂志,1998 12(4):175-176.

[2] Marquie C, De Geeter G, Klug D,et al. Postoperative use of heparin increases morbidity of pacemaker implantation[J]. Europace,2006, 8(4):283-287.

[3] Wiegand UK, LeJeune D, Boguschewski F, et al. Pocket hematoma after pacemaker or implantable cardioverter defibrillator surgery: influence of patient morbidity, operation strategy, and perioperative antiplatelet/anticoagulation therapy[J]. Chest,2004 ,126(4):1177-1186.

[4] Goldstein DJ,Losquadro W,Spotnitz HM. Outpatient pacemaker procedures in oral anticoagulated patients[J]. Pacing Clin Electrophysiol,1998,21(9):1730-1734.

[5] Giudici MC,Paul DL,Bontu P,et al. Pacemaker and implantable cardioverter defibrillator implantation without reversal of warfarin therapy[J]. Pacing Clin Electrophysiol,2004,27(3):358-360.

[6] Michaud GF,Pelosi F Jr, Noble MD,et al. A randomized trial comparing heparin intitiation 6 h or 24 h after pacemaker or defibrillator implantation[J]. Am Coll Cardiol,2000,35(7):1915-1918.

[7] alKhadra AS. Implantation of pacemakers and implantable cardioverter defibrillators in orally anticoagulated patients[J].Pacing Clin Electrophysiol,2003,26(1Pt 2):511-514.

备注/Memo

备注/Memo:
收稿日期:2007-04-25.作者简介:钱骏,副主任医师,硕士Email:qianjun.1969@163.com
更新日期/Last Update: